Basic Info.
After-sales Service
3 -5 Year
Application
Home, Industrial, Commercial, Base Station
Specification
Normal, 378x280x103mm
Communication Interface
USB/ RS485(Bluetooth/WiFi/GPRS)/ Dry Node Control
PV Charging Current
0-60A
Trademark
HonorInsight or OEM
Transport Package
Carton Box with Foam Paper
Product Description
2kVA 3kVA 5KA 24V Hybrid Inverter 2000W 3000W 5000W off Grid Solar Inverter
Product Description
HF series is a new all-in-one hybrid solar charge inverter, which integrates solar energy storage &mains charging energy storage and AC sine wave output. Thanks to DSP control and advanced control algorithm, it has high response speed, high reliability, and high industrial standard.
Overview
Basic system introduction
The figure below shows the system application scenario of this product. A complete system consists of the following parts:
1. PV module: Convert light energy into DC power, and charge the battery through the all-in-one solar charge inverter, or directly invert into AC power to drive the load.
2. Mains or generator: Connected at the AC input, to power the load while charging the battery. If the mains or generator is not connected, the system can also operate normally, and the load is powered by the battery and PV module.
3. Battery: Provided to ensure normal power supply to the system loads when solar energy is insufficient and the Mains are not connected.
4. Household load: Allow connection of various household and office loads, including refrigerators, lamps, TVs, fans, and air conditioners.
5. All-in-one solar charge inverter: The energy conversion unit of the whole system. Specific system wiring method depends on the actual application scenario. Detailed Photos
Product Parameters
Models | HF2420U60-100 | HF2430U60-100 |
AC mode | |
Rated input voltage | 110/120Vac |
Input voltage range | (90Vac~140Vac) ±2% |
Frequency | 50Hz/ 60Hz (Auto-detection) |
Frequency Range | 47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz); |
Overload/short circuit protection | Circuit breaker |
Efficiency | >95% |
Conversion time (bypass and inverter) | 10ms (typical) |
AC reverse protection | Available |
Maximum bypass overload current | 40A |
Inverter mode | |
Output voltage waveform | Pure sine wave |
Rated output power (VA) | 2000 | 3000 |
Rated output power (W) | 2000 | 3000 |
Power factor | 1 |
Rated output voltage (Vac) | 120Vac |
Output voltage error | ±5% |
Output frequency range (Hz) | 50Hz ± 0.3Hz/60Hz ± 0.3Hz |
Efficiency | >90% |
Overload protection | (102% < load <110%) ±10%: report error and turn off the output after 5 minutes;(110% < load < 125%) ± 10%: report error and turn off the output after 10 seconds;(Load >150% ±10%): report error and turn off the output after 5 seconds; |
Peak power(W) | 3000 | 4500 |
Loaded motor capability | 1HP | 2HP |
Output short circuit protection | Circuit breaker |
Bypass breaker specifications | 40A |
Rated battery input voltage | 48V (Minimum starting voltage 44V) |
Battery voltage range | Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery... settable on the LCD screen) |
Power saving mode AC charging | Load ≤25W |
Battery type | Lead-acid or lithium battery |
Maximum charge current | 30A |
Charge current error | ± 5Adc |
Charge voltage range | 40 -60Vdc |
Short circuit protection | Circuit breaker and blown fuse |
Circuit breaker specifications | 40A |
Overcharge protection | Alarm and turn off charging after 1 minute |
PV charging | |
Maximum PV open circuit voltage | 100Vdc |
PV operating voltage range | 30-100Vdc |
MPPT voltage range | 30-85Vdc |
Battery voltage range | 20-33Vdc |
Maximum output power | 1400W |
PV charging current range (can be set) | 0-60A |
Charging short circuit protection | Blown fuse |
Wiring protection Certified specifications | Reverse polarity protection |
Certification | CE(IEC/EN62109-1 |
EMC certification level | EN61000, C2 |
Operating temperature range | -15°C to 55°C |
Storage temperature range | -25°C ~ 60°C |
Humidity range | 5% to 95% (Conformal coating protection) |
Noise | ≤60dB |
Heat dissipation | Forced air cooling, variable speed of fan |
Communication interface | USB/RS485(Bluetooth/WiFi/GPRS)/Dry node control |
Size (L*W*D) | 378mm*280mm*103mm |
Weight (kg) | 6.8 |
Wiring Specifications and Circuit Breaker Selection Wiring and installation must comply with national and local electrical codes.
Recommended PV array wiring specifications and circuit breaker selection: Since the output current of the PV array is affected by the type, connection method and illumination angle of the PV module, the minimum wire diameter of the PV array is calculated according to its short-circuit current; refer to the short-circuit current value in the PV module specification (the short-circuit current is constant when the PV modules are connected in series; the short-circuit current is the sum of the short-circuit currents of all PV modules connected in parallel); the short-circuit current of the PV array shall not exceed the maximum input current.
Refer to the table below for PV input wire diameter and switch:Models | Recommended PV wiring diameter | Maximum PV input current | Recommended air switch or circuit breaker type |
HF2420U60-100 | 8mm2/8AWG | 40A | 2P-63A |
HF2430U60-100 | 8mm2/8AWG | 40A | 2P-63A |
Refer to the table below for recommended AC input wire diameter and switch:Models | Recommended AC input wiring diameter | Maximum bypass input current | Recommended air switch or circuit breaker type |
HF2420U60-100 | 8mm2/8AWG | 40A | 2P-63A |
HF2430U60-100 | 8mm2/8AWG | 40A | 2P-63A |
**Note: There is already an appropriate circuit breaker at the Mains input wiring terminal, so it is not necessary to add one more. Recommended battery input wire diameter and switch selection:Models | Recommended battery wiring diameter | Rated battery discharge | Maximum charge current | Recommended air switch or circuit breaker type |
HF2420U60-100 | 25mm2/3AWG | 100A | 100A | 2P-120A |
HF2430U60-100 | 30mm2/2AWG | 140A | 100A | 2P-160A |
Recommended AC output wiring specifications and circuit breaker selection:Models | Recommended AC output wiring diameter | Rated inverter AC output | Maximum bypass output current | Recommended air switch or circuit breaker type |
HF2420U60-100 | 8mm2/8AWG | 16.7A | 40A | 2P-63A |
HF2430U60-100 | 8mm2/8AWG | 25A | 40A | 2P-63A |
**Note: The wiring diameter is for reference only. If the distance between the PV array and the all-in-one solar charge inverter or the distance between the all-in-one solar charge inverter and the battery is relatively long, using a thicker wire can reduce the voltage drop to improve system performance. **Note: The above are only recommended wiring diameter and circuit breaker. Please select the appropriate wiring diameter and circuit breaker according to actual situations. Application
Address:
Room a, 13th Floor, Yifeng Building, S358 Provincial Road, Humen Town, Dongguan, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Industrial Equipment & Components, Light Industry & Daily Use, Lights & Lighting, Metallurgy, Mineral & Energy, Security & Protection, Service
Management System Certification:
ISO 9001, ISO 14001
Company Introduction:
Honor Insight IoT Technology Co., Ltd. is a high-tech enterprise dedicated to the research and development of the key technologies of the Internet of Things and big data as well as the promotion of industrialization, and to improve the intelligence level of enterprises, institutions and cities. The company chooses "simple and trustworthy, open and win-win" as its purpose, and always helps the government and enterprises to achieve efficient information management and zero emissions.
At present, the company mainly provides smart city lighting management system based on Internet of Things like LoRa, NB-IoT and other communication technologies, photovoltaic power generation off-grid and grid-connected systems, environmental monitoring systems, smart city platforms, private cloud construction and other services.
With ahead hardware and software solutions, supply chain channel integration capabilities, data value development capabilities and complete vertical service genes, we focus on the four major segments of smart PV, smart community, smart site and smart agriculture, together bringing a group of professional background talents from Baidu, Huawei, Tencent, Jinli, Yangzhi, Cisco, etc. In product planning, big data analysis, hardware access, UI design, mobile development, cloud building, system integration, data products and applications.